OPT3001 Ambient Light Sensor
The opt3001 sensor platform allows you to use your OPT3001
(datasheet)
ambient light sensor with ESPHome. The I²C bus is required to be set up in
your configuration for this sensor to work.

# Example configuration entry
sensor:
  - platform: opt3001
    name: "OPT3001 Illuminance"
    address: 0x44
    update_interval: 60sConfiguration variables
- name (Required, string): The name for the sensor. 
- address (Optional, int): Manually specify the I²C address of the sensor. Defaults to - 0x44(address if address pin is pulled low). If the address pin is pulled high, the address is- 0x45. If the address pin is connected to SDA, the address is- 0x46. If the address pin is connected to SCL, the address is- 0x47.
- update_interval (Optional, Time): The interval to check the sensor. Defaults to - 60s.
- id (Optional, ID): Manually specify the ID used for code generation. 
- All other options from Sensor.