# Example configuration entry
sensor:
  - platform: sps30
    pm_1_0:
      name: "Workshop PM <1µm Weight concentration"
      id: "workshop_PM_1_0"
    pm_2_5:
      name: "Workshop PM <2.5µm Weight concentration"
      id: "workshop_PM_2_5"
    pm_4_0:
      name: "Workshop PM <4µm Weight concentration"
      id: "workshop_PM_4_0"
    pm_10_0:
      name: "Workshop PM <10µm Weight concentration"
      id: "workshop_PM_10_0"
    pmc_0_5:
      name: "Workshop PM <0.5µm Number concentration"
      id: "workshop_PMC_0_5"
    pmc_1_0:
      name: "Workshop PM <1µm Number concentration"
      id: "workshop_PMC_1_0"
    pmc_2_5:
      name: "Workshop PM <2.5µm Number concentration"
      id: "workshop_PMC_2_5"
    pmc_4_0:
      name: "Workshop PM <4µm Number concentration"
      id: "workshop_PMC_4_0"
    pmc_10_0:
      name: "Workshop PM <10µm Number concentration"
      id: "workshop_PMC_10_0"
    pm_size:
      name: "Typical Particle size"
      id: "pm_size"
    address: 0x69
    update_interval: 10sConfiguration variables
- pm_1_0 (Optional): The information for the Weight Concentration sensor for fine particles up to 1μm. Readings in µg/m³. - All options from Sensor.
 
- pm_2_5 (Optional): The information for the Weight Concentration sensor for fine particles up to 2.5μm. Readings in µg/m³. - All options from Sensor.
 
- pm_4_0 (Optional): The information for the Weight Concentration sensor for coarse particles up to 4μm. Readings in µg/m³. - All options from Sensor.
 
- pm_10_0 (Optional): The information for the Weight Concentration sensor for coarse particles up to 10μm. Readings in µg/m³. - All options from Sensor.
 
- pmc_0_5 (Optional): The information for the Number Concentration sensor for ultrafine particles up to 0.5μm. Readings in particles/cm³. - All options from Sensor.
 
- pmc_1_0 (Optional): The information for the Number Concentration sensor for fine particles up to 1μm. Readings in particles/cm³. - All options from Sensor.
 
- pmc_2_5 (Optional): The information for the Number Concentration sensor for fine particles up to 2.5μm. Readings in particles/cm³. - All options from Sensor.
 
- pmc_4_0 (Optional): The information for the Number Concentration sensor for coarse particles up to 4μm. Readings in particles/cm³. - All options from Sensor.
 
- pmc_10_0 (Optional): The information for the Number Concentration sensor for coarse particles up to 10μm. Readings in particles/cm³. - All options from Sensor.
 
- pm_size (Optional): Typical particle size in μm. - All options from Sensor.
 
- auto_cleaning_interval (Optional): The interval in seconds of the periodic fan-cleaning. 
- address (Optional, int): Manually specify the I²C address of the sensor. Defaults to - 0x69.
- update_interval (Optional, Time): The interval to check the sensor. Defaults to - 60s.
Wiring
The sensor has a 5 pin JST ZHR type connector, with a 1.5mm pitch. (Matching connector housing, datasheet) To force the sensor into I²C mode, the SEL pin (Interface Select, pin no.4) should be shorted to ground (pin no.5)

For better stability, the SDA and SCL lines require suitable pull-up resistors. Sensirion shows 10 kΩ resistors between VDD (5V, pin no.1) and SDA (pin no.2) and SCL (pin no.3) in the manual.
Automatic Cleaning
The SPS30 sensor has an automatic fan-cleaning which will accelerate the built-in fan to maximum speed for 10 seconds in order to blow out the dust accumulated inside the fan. The default automatic-cleaning interval is 168 hours (1 week) of uninterrupted use. Switching off the sensor resets this time counter. Disabling of automatic-cleaning or setting a manual interval is not supported at the moment.
Manual Cleaning
This action manually starts fan-cleaning.
on_...:
  then:
    - sps30.start_fan_autoclean: my_sps30To be able to trigger the fan cleaning feature from Home Assistant, add a button as shown below, and trigger it with a (periodic) automation.
button:
  - platform: template
    name: "SPS30 fan clean"
    on_press:
      then:
        - sps30.start_fan_autoclean: my_sps30
sensor:
  - platform: sps30
    id: "my_sps30"
    ...Sensirion recommends cleaning at least once per week.